$10.50 Flat Rate Shipping available on all Maytronics Replacement Parts. Issues with tangle free swivel cord shorting out?, ussues with cleaning steps? I have no DC. Any help would be greatly appreciated. The equipment lasts for many years, often outliving the natural life of the included AC adapter. Most multimetershave morefunctions than we will use, For this series of tests, we will only be using the AC or DC voltage and continuity test functions.

9995670, PD 5012, SN HG5012A10956 The power supply is putting out 21.2 VDc (measured right at power supply). Also, does one motor /impeller keeping working while the other turning off soon indicate a motor problem or maybe a yet to be found mechanical problem? You would need to do some of the troubleshooting mentioned in the guide if you want any certainty. Figuring possibly a blown motor? Your loyal Nautilus Plus Robotic Pool Cleaner has probably put in years of service under tough conditions without complaint. Multi-media filtration includes 3 filter options: bottom-load fine cartridge filters, ultra-fine cartridge filters, and a large fine filter bag. My Dolphin pool cleaner supply arrived right on time and works perfectly. Not only is pool maintenance business, in our spare time it's our hobby! The motor is receiving power but is not turning; if the shafts are frozen, the motor is dead and should be replaced. Posted: 3/14/2022, Gerald T Tschura TEST 2A- CHECK POWER CORD - Pull the power plug out of the Power Supply to test the power cord between the wall outlet and the power supply. End of cable going to motor (3 pins): 28, 26 and 1.9 for the different pin combinations The top impeller and drive tracks quit working. Posted: 3/21/2022, Dolphin premier stop moving after minutes or secs If you see a reading of between 120V and 130V, your wall outlet is good and you have successfullypassed Step 1. Whether or not the track spins could have more to do with guide wheels and brushes than the motor itself. With Dolphin, pool surfaces and water are left clean and healthy, every time. Read our guide to the different types of swimming pools before making your decision. I have checked/disassembled the moving parts outside the motor unit to make sure everything is clean and moving freely. The Maytronics 99956035US-F1 Dolphin Power Supply has a 115V Voltage Rating, 100-250 VAC Input, 29V DC 120W Output, with a Frequency Rating 50/60 Hz Features. You can also purchase disposable filter bags if you wish. No humming or signs of life from the motors. The Dauphine cleaner works great .But only stays in one area of the pool around a 20 foot area.Does not go to ends of pool.Vacuum works great just dont get around all or pool. Once we sell out, we can't guarantee this amazing price. I don't know if it is supposed to spin freely, turning both ways. I have checked all of the cables everything seems fine. However, the caddy is very useful for transporting and storage. Your pool cleaner may be just a simple AC replacement away from being fully operational once more. This top-tier Maytronics Dolphin Power Supply, Oh, and we have one more little offer for you: any, Pool Auto Fill Float Valves & Water Levelers, Maytronics Dolphin Power Supply Bracket / Caddy Adaptor | 9980038, Maytronics Dolphin Power Cable 7' | 5898412LF. [emailprotected]. Have you done any of the troubleshooting? So, why replace your entire unit if everything else is still in tip-top shape? While youll get what you pay for with most appliances, with the Dolphin Premier, it doesnt come with any extra accessories. It comes on for a bit then the just turns off the reset button and test button wont work on the black power cable clicks off straight away. Kaysville, UT 84037, Copyright 2022 All Rights Reserved. It is machine washable and can be hosed out, but takes some time. One customer suspected the floats on the handle werent properly positioned, so thats something you might want to research. Then place the meter probes into the plug on the motor end of the Cable. In our informative article, youll discover the causes of a cloudy pool and how to fix the problem. Be careful not to touch theprobes across the wires or you will short them out. So come on down to Wild West Pool Supplies, where the water is always clean, cool and fun to dive right into! There's no reason to even consider risking an unofficial replacement pool cleaner PSU. When the cleaner does run intermittently, is it herky-jerkyor does it run as usual? Could you tell me why our power supply unit wont stay on. Turn the power supply ON. Website creation in Evergreen, Colorado by AlphaPixel Reach. Resistance of cable: 0.9, 0.6 and .OL (open) for the 3 different wires TEST 4- CHECKPOWER SUPPLY FUSE - If you have an older style Power Supply, it will have a fuse inside that can be checked for continuity to see if it failed. TEST 1B - If you see 0V on your multimeter, check the following: Circuit Breaker may have tripped; the GFCIat your outlet has to be reset; or your outlet is bad and needs to be replaced. The filter bag performed better than the cartridges in picking up leaves, sticks, and other large debris. Simplicity and enjoyment are built-in to every Dolphin robot.

Using a Phillips head screwdriver, unscrew the middle screw and lift off the Impeller cover. PRECAUTION 1 - During the operation of your cleaner, Make sure that your pool is free of toys or small objects that can get lodged in your cleaner and burn up the motor. Ran the tests recommended and no DC voltage comes out the amphenol plug or wires into back of plug. Youll find everything you need to know to set one up. Fits several models of Dolphin pool robots. Made by the robotic pool cleaner leader, Dolphin robots reliably deliver outstanding cleaning performance. Then unscrew theAmphenol Plug with a Phillipshead screwdriverandpull itout of the Power Supply. The "open" reading means there is no circuit continuity; I presume you need a new cable. Trying to determine if i need a new motor unit, power supply. No other automatic, residential pool cleaner comes close to Dolphin robots ease of use, performance, and reliability delivering years of cost-effective pool cleaning. How To Start A Pool Cleaning Business in 17 Steps, LED indicator to signal when debris bag is full. The power supply is 2 years old. Homeowners with trees around the pool commented on how well this machine worked. Maytronics rigorously tests their products, and backs them with a warranty guarantee against short-term malfunctions. Posted: 4/21/2021, Vinny Authorized Service Center and Elite Dealer. Trying to determine if my motor is faulty, or if spinning only one way out of water is normal. Then drop us a line! I forgot how to have my dolphin map the pool.

Do you have any questions or concerns about replacing your Nautilus Plus power supply? I ran diagnostic tests on my Maytronics power supply, P.No. If you get 0V DC on the raw wire, you will have to test the fuse inside thePower Supply for continuity. my power light switch will light up but the 1 2 3 cycle lights will not come on. I tested the cable for continuity and its good. Cleaner, crisper pool experiences are coming your way. It sounds like your impeller motor has failed. Any thoughts? It sounds like you have a power supply failure. Could this be a power supply issue or is something else likely? Almostall of Dolphin's power supplies sold for units in the US are meant for 115V. Posted: 12/8/2020, InyoPools Product Specialist Matt S. The power outlet, and supply cable test good, 120 v. When first powered on, the blue lights come on, and 29 v register on the DC out. Troubleshooting: It will feel heavier than before due to the water and debris in the filters. Posted: 3/12/2022, InyoPools Product Specialist Matt S. Thanks. Any boards or internal fuse etc. What is the part number of your power supply? The meter should read close to 29V DC. PULL THE POWER CORD OUT OF THE WALL OUTLET. The cartridges easily snap in and out and can be quickly hosed clean. Thank You for your time. the upper limits of which are labeled 2, 20, 200, and 600. If continuity fails, you will have to replace theAmphenolPlug. Virtually no explanation of the smart tech features. If the Pool Cleaner does not respond, your motor is bad.

Posted: 7/26/2020, InyoPools Product Specialist Matt S. The impeller (in perfect condition-new) will not start, however, the wheels are working fine. It appears to be sealed pretty well. If you are testing for voltages between 0 and 200V, youwould set your meter to 200. These are absolutely huge deals, across all of our pool and spa offerings. Posted: 12/9/2020, Don Robotic pool cleaners like the Nautilus Plus draw a great deal of power for normal operation. Posted: 8/20/2021, InyoPools Product Specialist Matt S. This deal isnot too good to be true.

TEST 2B- Insert the twomultimeterprobes into the female end of the power cord The meter should be set to 200V AC asused in Step 1. Posted: 8/11/2021, Pool Daddy What is the part number of your power supply? Sign up to be the first to know about sales and promotions! Since then, hes worked in a variety of industries, including design and construction of luxury swimming pools. For more information on this coverage, please consult the owner's manual or contact Maytronics. Combine this with dual scrubbing brushes and the mapping software, and you get a more thorough clean faster than the more basic pool robots. The correct replacementfor your cable is the. Maytronics 58984402LF Digital Power Supply Cable, How To Measure & Install A Swimming Pool Liner, This product is for the Maytronics cleaners only: S200 99996202-US, S300 99996221-US, S300i 99996225-US, Active 20 99996023-US, Active 30 99996231-US, Active 30i 99996235-US, Prowler 920 99996201-US, Prowler 930 99996214-US, Discovery 99996201-DIS, Saturn 99996114-SAT, Cayman 99996135-SPL, Quantum 99996203-SPL, Premium 99996211-PIO, Input: 100-125VAC 50/60 Hz 2A Output: DC 29V 120W, Black Power Cord is NOT included it is sold as a separate part number 5898412LF, Maytronics Cable For Digital Power Supply, 5898412LF, For the following Maytronics cleaners only: S200 99996202-US, S300 99996221-US, S300i 99996225-US, Active 20 99996023-US, Active 30 99996231-US, Active 30i 99996235-US. By submitting your payment, you agree to our terms and conditions. Call 303-985-0077 if you do not see the part you need or if you need assistance with pricing or troubleshooting. Thanks! Please help! TEST 5C -Pull the Cable out of the top of the motor. Thanks. Reattach the DolphinCover and ImpellerCover. TEST3A - CHECK AMPHENOLPLUG - Reconnect the power cord to the Power Supply. Thinking about buying a pool? If your Nautilus Plus no longer functions, don't fret! Amphenol plug (3 pins) DC voltage: 28, 26 and 1.9 for the different pin combinations Does the 2.6v voltage difference between two powered pins mean the power supply is ok, or that it needs replacement? This 7' cord should cover most use cases, and it is guaranteed to work out of the box thanks to the Maytronics branding. The cleaner m0tor has two functions, to run the drive shaft that turns the tracks and the shaft the spins the impeller. It appears you found the issue, the wire is broken and the resistance reading is "open." Several customers reported that the Dolphin Premier crawls over pool drains and other obstacles without getting stuck or confused. Posted: 9/8/2021, Johnathan Dixon Your pool cleaner may be just a simple AC replacement away from being fully operational once more. Power supply lights up and I can select any of the three weekly programs, but the motor never starts either in the water or on dry land. Any ideas? caddy dolphin robotic triton maytronics cleaner assemble pool inyopools All Maytronics Parts Available. If you are testing for voltages above 200V and up to 600V, you would set your meter to 600V. Depending on the age of the cleaner, it may be best to get a whole new unit because motors are expensive. Find out what the dangers are and what you can do about them by reading our article. Set the meter for a continuity check. Does this indicate that a new power supply is needed? If the brushes have any plastic covers on them, remove those. You can easily switch between automatic cleaning cycles or manual with simple controls on the power supply. Posted: 8/17/2021, Laura If you see 29V DC, the AmphenolotorPlug is good and you can gotoTest 5A to check the DolphinMotor. Dolphin Pool Cleaner Power Supply 9995678-US-ASSY, The power supply was great quality and was delivered on time, 471 S Deseret Dr 7777 W. Jewell Avenue How can you rate it so high when it has had issues with cleaning pools with curved ends? TEST2C - If the reading on the meter is OV, Check for a break in the electricalwiring of the cord. Posted: 5/23/2020. You can drop it in, and it will go through its cleaning cycle. Its machine washable but can be hosed out as well. Please make sure your pool cleaner is on the list above. Note how the wires areattached so you can replace them correctly when the plug is reattached. Model 9995678 power supply, Power light comes on steady, no mode selection lights come on any longer. There won't be much sense in spending a lot on a cleaner motor if the chassis does not last a couple of more seasons. The equipment lasts for many years, often outliving the natural life of the included AC adapter.

I checked the power going into the motor and it reads 27v There is 29v coming out of the power supply. Cleaner, crisper pool experiences are coming your way. Posted: 4/22/2022, InyoPools Product Specialist Matt S. It could be a bad transformer or board in the power supply. Some customers said the machine was too wide to clean their narrow pool steps, so manual brushing may be needed with those. A few days later after repeated trying, it ran.. but only for a day or so. If not, are there steps to open the power supply??

If the continuity check on the fuse is negative, replace the fuse. Our customers who bought in years ago are now increasingly looking into replacing their aging power supplies. Germs and bacteria can cause life-threatening illnesses in a swimming pool. TEST 1A - CHECKWALL OUTLET -The power at the outlet should be around 120V so set the meter for 200 on the AC side of the multimeter. If the meter shows 0V DC go toTest 6A. TEST 5A - TEST DOLPHINMOTOR - To test fora bad motor you will have to disconnect the Cable from the top of the motor. Posted: 4/16/2021, Joel We will never hesitate to pass along any tips or advice. Same Day Shipping. Posted: 8/9/2021, InyoPools Product Specialist Matt S.

Looks like one of the wires in the cable is broken. Unlike most AC-motor pool cleaners such as suction and pressure cleaners, the Dolphin Premiers dual DC motors use 90% less energy. When I test my nautilus cc plus out of water, is is the track supposed to spin only one way, or spin one way, then reverse the other way? You have tested the pins on the power supply, but what about steps 17 to 23? You show only 2 wires coming into the amphenol plug. pool robotic cleaners ground automatic cleaner aquabot junior I took everything off the motor that would be a load and plugged it into the power supply, but get the same result. Posted: 9/3/2020, Rick On the 3 power supply pins, i get differential voltages of 28.8, 26.2, and 2.6v when the robot is not connected. For the following Maytronics cleaners only. Posted: 4/25/2022, Nautilus CC Plus Out of Water Test There's no exact date when this offer runs out, but you'll want to get yours soon. Posted: 9/7/2021, InyoPools Product Specialist Matt S. If it was a power supply issue, the motor wouldn't run at all. The cleaner doesn't remember a map of the pool. Oh, and we have one more little offer for you: any Maytronics customers this month will get special access to our exclusive offer list. More about the Maytronics Power Supply9995670-US-ASSYRobotic pool cleaners like the Nautilus Plus draw a great deal of power for normal operation. Posted: 6/2/2022, Claybert Coury Posted: 7/18/2020, Anonymous Use the handle to lift the robot from the pool and NOT the cord. Some local service centers werent able to do the repairs either because they werent capable or because customers didnt purchase the robot directly from them. Posted: 5/26/2020, InyoPools Product Specialist Matt S. This part, at this price? TEST 3D - Remove theAmphenolPlug from the wires withasmall Allen wrench. What is the part number of the power supply? We discuss the danger and what you can do about it! With a range of automation options, they are made to set and forget. Plug the power cord back into the wall and turn the Power SupplyON. Or do you just want to clean it whenever you think about it? Can I replace that fuse or do I have to replace the whole board ? Not quite sure how to interpret the voltage on the amphenol plug. The remote, according to several people, is pretty useless. Maytronics Dolphin Power Supply9995670-US-ASSYfeatures: The Nautilus Pro is one of the best pool cleaners on the market, and even the best PSUs have trouble lasting quite as long as this industry-leading pool cleaner. If I unplug the cable and power on the power supply , the 3 lights blink and the power stays on like usual. Once powered back on, the same cycling happens, lights stay on for 2.5 mins or so, power 29v on DC out, then fades to 00 again. Either CS was unresponsive or requested they ship the whole unit back. There are several tests we show to narrow down the possibilities. Back to same problem. DIAL METER FORDCTEST -TheDC side of the meter hasfour test ranges. An educated guess would lead me to say it is a bad motor. Thank you for making this post. Place the other probe onone of the leads on the other end of the cord thatplugs into the wall outlet. The bags are great for holding large debris like sticks, leaves, seeds, and bugs. Its packed with smart tech features and can clean an in-ground pool up to 50 feet within 3 hours. This guide shows you howto troubleshootthe electrical circuits of the MaytronicsDolphin Pool Cleaners so you can isolate your problem and replace the failed parts or parts. If the fuse tests positive, the Power supply has an internal problem and you will have to replace the Power Supply. Our customers can rest assured: the Maytronics Dolphin 9995670-US-ASSY Power Supply comes with a one (1) year warranty directly from Maytronics. TEST 6A - CHECK THE DOLPHINCABLE - If you have 29V DC coming outof the PowerSupply into the Cable (See Step 3B) and 0V DCat the motor end of the Cable, you will want to run a continuitycheck on each wire in the Cable to verify that the Cable is broken and needs to be replaced.Remember to unplug the Cable at the PowerSupply end. Suite #2 Lightweight and durable, this caddy makes storing and transporting your pool robot easy. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); We love helping homeowners find quality cleaning products they can afford.

Its bad. I have the nautilus preimer. Don't over tighten. The navigation system and scanning features allow this pool robot to clean the walls, floor, and waterline using the most efficient path for a quicker clean. If the readingis between 120V and 130 V, the power cord is good and you can proceed toTest 3A. Then plug in the power supply. I will work through the steps you have listed here and hopefully it is a cable issue. Its a 09/2005 model yellow. Dolphin robotic pool cleaners clean any type or shape of pool efficiently and thoroughly. For one thing, the red clean filter light comes on in about 5min. What do you think? DIAL METER FOR AC TEST - The AC side of the meter has two test ranges. Maytronics Dolphin 9995670-US-ASSY Power SupplyPool Cleaner. Is there a way to test each motor individually and also the control board? TEST 3B - Set your multimeterto 200 on the DC side of the meter. I have a Maytronics 99996333-DX3 Dolphin Robotic Pool Cleaner. But we list a few different ways to troubleshoot the motor in the guide correctly. Posted: 9/23/2020, CDS DIAL METER FOR CONTINUITY TEST -A continuity test measures for a break in an electrical line, like the Dolphin Cleaner cable. Place one probe in one of the holes in the female end of the power cord. Copyright 2017-2022 Cleanup.Expert (Life Sciences Discovery Group), Dolphin Nautilus CC Plus Robotic Pool Cleaner. What is the part number for your specific power supply? This is where this robotic pool cleaner really shines. Dolphin pool cleaners offer the most efficient and cost-effective method for achieving a consistently clean pool. Posted: 9/8/2020, InyoPools Product Specialist Matt S. Posted: 4/13/2021, InyoPools Product Specialist Matt S. Posted: 8/16/2021, InyoPools Product Specialist Matt S. If the meter shows 29V, you are getting power to the motor. the whole power supply is the. One issue that might be a non-issue was the foam roller that seemed to have gotten flattened on one side during shipping. Check out our guide on how to start a pool cleaning business. Reattach the Cable to the Power supply. Our pool maintenance expert, Luke Reed, earned his BS in Civil Engineering from Georgia Tech in 1998. Phone: 303-985-0077 OVERVIEW OF TESTS - This picture lists the 6 tests we will conduct to isolate your Dolphin electrical problems. The voltageshould be around 29 volts, like the 2-wire version. TEST 3F- To test the AmphenolPlug for continuity, first make sure the meter is in continuity mode. Posted: 8/23/2021, Kevin Fitz It is compatible with all standard full AC cords, and Maytronics offers a specially branded version with their guarantee behind it. Power supply is putting out 29v, the end of the cable at the motor reads 27 but no go. Our primary tool for testing these electricalcircuits is a multimeter/voltmeter so we will first cover some of the basics of how to use a multimeter.Click Here to View Replacement Dolphin Pool Cleaner Parts, Ty But that is a guess. So why wait? MAJOR DISCOUNT ALERT FOR POOL OWNERS: This power supply for the Nautilus Plus Robotic Pool Cleaner is the worry-free official replacement you need, and it's availablenowat an absolutely bonkers 15% off MSRP -- with FREE shipping in the Continental US, to boot! TEST3E - To retest thevoltage coming out of the Power Supply first TURN ON THE POWER. Just replace the cable or is the power supply bad as well? As long as our current supply holds out, this offer stays. If your Power Supply is newer (without screws), it does not have a fuse and you will have to replace thePower Supply. THE Leading Experts of Maytronics Dolphin Replacement Parts and Robotic Pool Cleaners. STORE HOURS: Monday thru Saturday: 10:00 am to 5:00 pm Sunday: Closed. I am trying to troubleshoot my Dolphin Premier cleaner. Then place the two probes from the multimeterinto the wall outlet. This machine is fairly light at 22 pounds. Privacy PolicyTerms & ConditionsImage Copyright, Above Ground Pump & Filter Equipment Set Parts. Posted: 9/10/2020, Gary Mclees Though the reusable filter bag holds a lot of debris, its not particularly easy to clean out. Hello , My DX3 will not move nor will the impeller. Posted: 4/5/2022, InyoPools Product Specialist Matt S. When powered on only the three blue lights,,, not the amber, The three blue lights flash for about a while then go out. It also goes over the same area, over and over. If it is not, this will not work and you are responsible for return shipping. It saves me time and energy, especially when the pool is opened and has a winters worth of stuff on the bottom of the pool. Put the power supply about halfway down the long side of the pool and at least 12 feet from the edge. The DC out plug has continuity. If it reads 0V, move the probe to the other lead of the wall plug. 13 year old Dolphin M4 Supreme suddenly stopped working I'd go with those, as they are a more accurate way of testing the equipment. To get to the endof the Cable, first TURN OFF POWER. Posted: 5/29/2022, InyoPools Product Specialist Matt S. I have a maytronics DX3 pool cleaner and the power supply have 123 volts going in to the power supply and there are 63 volts coming out of the power supply. I pull the filter out and it is empty. Hi. Twist the plug counter-clockwiseuntil it comes out and thenslide it down the Cable. It has provided me and others a lot of good information. You want to make sure you are testing the ends of the same wire for continuity. Several people appreciated that all the filters are included without having to buy them separately. Move the probes to the ends of the other wire and test it for continuity, If you don't have continuity on both wires, the cord is bad and needs to be replaced. TEST5D - Set the meter to 200 DC and check that the Dolphin Cable is attached to the Power Supply. Lowest Prices Guaranteed. You are missing a '9' at the beginning of both of those part numbers. It may take a little effort. Dreaming of entrepreneurial success? What do you do when your MaytronicsDolphin Pool Cleaners stops running or there are no lights on the Power Supply? Easy to operate, and with easy filter emptying and cleaning, they do the work, so you dont have to. Yes, if the motor is receiving power but still is not moving, you have a blown motor. Cleaning unit itself is not coming on. Exclusively at Wild West Pool Supplies, we can now proudly offer our best price yet on the Maytronics Power Supply9995670-US-ASSY. When running this test, the POWER MUST BE OFF, and the meter should be set at the continuity setting as shown. Very basic. Posted: 4/14/2022, Tim Cleanup.Expert is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com and affiliated sites.